Chapter 4 — Troubleshooting and Maintaining the Printer
PD41 and PD42 Commercial Printer User’s Manual 75
7 Press the Print button once or press the Cancel soft key ( ) to
exit Dump mode.
8 You can also save the dump by pressing the Save ( ) soft key.
Using Extended Testmode
Use Extended Testmode to run additional tests such as:
printing test labels.
running a Testfeed in slow mode.
entering Dump mode.
resetting to factory defaults.
To run Extended Testmode
1 Make sure the printer is turned off, loaded with media, and that
the printhead is lifted.
2 Press and hold the Print button.
3 Continue to keep the Print button pressed down and turn on the
Power switch. After approximately ten seconds, the printer enters
Extended Testmode.
All three LEDs flash rapidly four times to signal that Extended
Testmode is active.
4 Release the Print button and lower the printhead. You are now in
Extended Testmode and the following screen appears.
TEST
SELECT MEDIA
Page view 88